Precision Thickness Gages
UPG-07 Monochrome

UPG-07 Monochrome

 Danatronics™ UPG-07 Monochrome series comes in 5 models ranging from our UPG-07B to the fully loaded UPG-07DLW that includes B-Scan, a 100k reading datalogger and a live Waveform (A-Scan)

UPG-07 Series of hand held ultrasonic precision gages are available in 4 models. Our UPG-07 series is the ideal unit to non-destructively test the wall thickness for manufactured parts requiring unprecedented accuracy and resolution. The UPG-07 series utilizes single element transducers and offers a 30 Mhz, square wave pulser, .0001” or 1 micron resolution with the ability to store and re-call 30 unique applications. So if you are measuring light bulbs, plastic bottles, golf clubs, coil steel, thin aluminum, aircraft parts and even pure gold bars, the UPG-07 series is the right choice.
REQUEST A QUOTE
Features:
  • .0001" Resolution
  • Live color A-Scan
  • Vibration and color change on alarm
  • Stored and recall of setups
  • 30 Mhz. bandwidth
  • Squarewave pulser
  • Zoom auto tracking to center waveform
  • 100 K reading datalogger
  • Multiple modes for challenging applications
  • Gain, range and blanking adjustments
  • Available in multiple models

Typical Applications:
  • Coil Steel
  • Castings
  • Rubber...Tires, Conveyor Belts
  • Fiberglass...Boat Hulls
  • Gel Coating
  • Plastics...Bottles, Toys, Tubing
  • Ceramics
  • Titanium...Golf Club Heads
  • Brass
  • Aluminum
  • Glass
REQUEST A QUOTE
 The UPG-07 monochrome series comes in 5 models

UPG-07B
Hand-Held Digital Ultrasonic thickness gage including: Plastic Carrying Case (PC-09), 2 Oz. bottle of couplant (C-02G), 2 AA batteries, a transducer 10 Mhz. or less (please specify), lemo to mircrodot cable 6' (LM-06)
UPG-07B


UPG-07
Includes all of the features of the UPG-07B plus gain, differential, velocity mode, and the ability to store and recall up to 30 custom setups.
UPG-07


UPG-07DL
Includes all of the features of the UPG-07 plus 100,000 thickness readings via internal Datalogger, B-scan, protective pouch (PP-09), USB cable
UPG-07DL


UPG-07W
Includes all the Features of the UPG-07 plus a Live Waveform to adjust gain, range, blanking, rectification. This model (Waveform) is highly recommended when setting up on difficult applications. Note: this model does not include the Datalogger.
UPG-07W


UPG-07DLW
All the features of the UPG-07W plus 100,000 thickness readings via internal Datalogger, B-scan, protective pouch (PP-09), USB cable
UPG-07DLW
REQUEST A QUOTE
 Size: 5" (127 mm) (L) x 3" (76.2 mm) (W) x 1.25" (31.75 mm) (H)

Weight: 8 OZ (.23 kg)

Thickness range: 0.020 - 20 inches (.50 mm - 508 mm) in steel, depending on material, temperature and transducer selection

Material Velocity Calibration Range: 0.0200 - 0.7362 in/uS (0.508 - 18.699 mm/uS)

Temperature: Gage Operating: -4° F to 122° F (-20° C to 50° C) High temperature transducers available for material temperatures from -5° F to 950° F (-20.5° C to 510° C)

Battery life: Up to 50 hours (20 hours with backlight on)

Battery type: 2 "AA" Alkaline

Display: 128 X 64 Graphics LCD monochrome, sunlight readable

Language support:
multi language of English, French, Spanish, Italian, Czech, German, Portuguese, Slovak, Finnish, Hungarian and Chinese on select models

Information displays: Loss of signal (LOS), min, max, large reading while displaying min at the same time, velocity, zero, calibration, units, freeze, unfreeze, % battery life remaining, gain - low, std, high, echo to echo symbol

Resolution:
.001" (.01 mm), .01" (.1mm) user selectable

Probe recognition: Via a pick list from a menu

Delay line auto zero measurement: Auto at power up with listed numeric value. Ideal for correcting delay line wear/curvature and for transducer acoustic drift at elevated temperatures

Package: IP54 rated Custom, splash-proof, high impact plastic with illuminating rubber keypad for go/no-go testing

Bandwidth: 0.5-20 MHz (-3dB)

Units: English/Metric/Microseconds

Gain: Low, Standard and High for varying test conditions (for gages without a waveform) or 1 dB steps from 20-90 dB or Automatic Gain Control (AGC) for gages with a waveform

Fast Min/Max Mode:
Simultaneously displays minimum or maximum and actual thickness value at 20 measurements per second

Differential Mode: Displays the difference from the actual thickness measurement in absolute or percentage of a user entered reference value

Alarms: Minimum/Maximum depth, vibrates, beeps and display flashes as well as keypad illumination

Illuminating keypad:
F1 = Red, F2 = Yellow and F3 = Green for easy go/no-go testing

Ergonomics:
User selectable lefty or rightly display changes via keypad

Backlight: Light Emitting Diode, On/Off or Auto On based on valid readings or last key press

Shut off: Auto, user programmable time out (1-31 minutes), after no reading/key press or never shut off

Protective pouch: Custom molded pouch with wrist strap and belt clip (Optional, standard on DLW and DL gages)

Transport case: Hard Plastic with high density molded foam cut out for gage and most accessories

Freeze mode: Freezes display (ideal for high temperature readings)

Hold mode: Holds display to retain last thickness reading

Standard EHC-09 Wave Series includes: Ultrasonic thickness gage, DKS-537, 5 MHz 0.375 inch diameter potted cable, operational manual, Data XL interface program, couplant, and transport case. See chart below for standard inclusions for each gage

Warranty: Limited 2 year warranty on parts and labor for gage only under normal use

Transducers:
A wide variety of dual transducers from 1-10 mhz, high temperature duals, delay lines and pencil probes. Note the EHC-09A only works with the DK-718, DK(S)-537 and the DC-250.
REQUEST A QUOTE
UPG-07 Software Options are easy and convenient to upgrade in the field.   Danatronics gage upgrades are done directly from your gage's keypad and do not require the use of a computer.

The following are available upgrades for the UPG-07 Monochrome Series

Datalogger
Comes standard with the UPG-07DL and UPG-07DLW

The datalogger stores 100,000 alpha numeric data points or thousands of waveforms (if gage is equipped with waveform option). Thickness values along with the i.d. information and all gage set up parameters are exported to Microsoft excel via the no-charged, Data XL interface program. Our Datalogger also interfaces with Ultrapipe. 
Datalogger


Live Waveform
Comes standard with the UPG-07W and UPG-07DLW

The live waveform (A-scan) is used to verify reading stability. With the live waveform the operator can adjust gain, range, rectification and 2 forms of blanking to set the gage to ignore unwanted noise or mode converted echoes.
Live Waveform
REQUEST A QUOTE
 The following accessories are available for the UPG-07 series

Spring Loaded Holder
The spring loaded holder (SPH-718) is the ideal fixture to be used on small diameter applications such as tubing to prevent the probe from rocking. Shown above is the SPH-718 with the DK718 transducer inside. The probe can be rotated as well and the fixture has v-notches to assist in probe alignment.
Spring Loaded Holder


5 Step Test Block
We offer a 5 step test block, made of carbon steel with nickel plating engraved in both English and Metric values from .100’, .200”, .300”, .400”, .500” or 2.54mm, 5.05mm, 7.5mm, 10.0mm, 12.7mm (No certification is provided with these blocks but can be provide on special order for an additional fee)
5 Step Test Block


Protective Pouch
Custom protective pouch Part Number PP-09 for the EHC-09 Series.
Protective Pouch


UPG Transport Case
The UPG Transport Case is shown with common inclusions. (Pouch, Spare batteries and 5 step test block sold separately).
UPG Transport Case


Cables
Dual and single cables offered in 6 feet or other lengths upon special order. Shown left to right: DLM-06, DLM-06ACMP, LM-06
Cables


Couplants
We offer a variety of ultrasonic couplants from a standard gel in 2 Oz. or 12 Oz. options, to high temperature up to 1100 Degrees F. Contact us for more details.
Couplants


AC Power
With this hardware upgrade, the EHC-09 can be used with AC Power (please note, this is not a re-charging system). In other words, with this option, the EHC-09 can be either used with AC or battery mode.
AC Power


Footswitch
With this hardware option the operator can use a footswitch to save, freeze or send readings.
Footswitch
REQUEST A QUOTE
 Danatronics offers a wide variety of single element transducers from .5-20 Mhz , including, contact, delay lines including pencil probes and immersion transducers for special applications. Consult Danatronics or one of our authorized representative for the proper use and recommendation for your application.

For complete list including specifications please see our transducer chart

Single Element Contact Transducers
Danatronics single element transducers are stocked in a wide variety of frequencies and diameters, from 0.5mHz to 10mHz. All single element probes come standard with microdot connectors
Single Element Contact Transducers


Delay Line Transducers
Danatronics delay line transducer are available in 5, 10 and 20 mHZ options.
Delay Line Transducers